EPOCH 4B Ultrasonic Flaw Detectors
The
EPOCH 4B flaw detector combines low cost, simple operation and great
performance. It has many of the flaw detection features offered by the
advanced EPOCH 4 flaw detector but offers fewer software options and a
less extensive datalogger.

Download pdf Brochure
(192 kb)
STANDARD FEATURES
-
Selectable, tunable
square wave or spike excitation pulser
-
Light, ergonomic design
(5.7 lbs/2.6 kg)
-
High-power NiMH battery
-
High resolution ELD or
LCD with full/split screen views
-
Automated transducer
calibration
-
Fast, minimum 60 Hz
electronics update rate
-
Full screen capability
of 200 in (5,000 mm) longitudinal velocity of steel (expandable to 400
in or 10,000 mm)
-
Minimum range capability
0.16 in or 4 mm (expandable to 0.038 in or 1 mm)
-
Display freeze holds
waveform and soundpath data
-
Soundpath data viewable
in inches, millimeters or microseconds
-
RF display mode
-
Alarms, threshold
positive/negative or minimum depth
-
Dual gates with optional
echo-to-echo measurements
-
Security key permits
remote upgrade of software options
SOFTWARE OPTIONS
GageView Pro Interface Program
The optional
GageView Pro
interface program adds many practical editing, documentation, review and
interface capabilities to the EPOCH 4B flaw detector. It helps manage and
format stored inspection data for convenient transfer to or from other
software applications.
DAC (Distance Amplitude Curve) with Alarm
Calculates signal
amplitude as a percentage or dB difference of the DAC curve level (ASME,
ASME-3, or JIS). Same-size reflectors peak along the curve independent of
their location. An alarm is activated when a gated signal breaks the
curve.
Low PRF (Pulse Repetition Frequency)
Reduces or eliminates
"wrap-around" noise by setting the PRF to a fixed 30 Hz. This feature is
often necessary when inspecting materials that are highly attenuating or
have long soundpaths.
TVG (Time Varied Gain) with 40dB Dynamic Range
Corrects for
distance/amplitude variations due to material attenuation and beam
spreading. Reference echoes are brought to a standard full-screen level of
80%.
Expanded Memory
Increases datalogger
capacity from 500 waveforms/10,000 thickness readings, to 2,000
waveforms/40,000 thickness readings.
AWS D1.1 & D1.5
Provides a dynamic
reflector “indication rating” for various AWS weld inspection
applications. This allows for a more efficient inspection by eliminating
manual calculations.
Narrowband Filters
Allows operator to set
narrowband filters around frequency of interest to improve signal-to-noise
ratio.
Echo-to-Echo Thickness Measurements
Allows operator to make
true metal thickness measurements when the outside of the surface is
painted or coated.
Extended Range
Extends Standard Range specifications: 0.038 to 400 inch (1 to 10,000mm).